Version 1 units manufactured after Feb. 7, 1999
20. Remove the display housing per Procedure 7.3. Remove the rear cover.
21. Tie one end of a stout string (at least 12’ long) to the upper end of the old interconnect cable
(display housing end).
22. Carefully pull the old interconnect cable out of the access hole near the lower PCA while
feeding the string into the unit. When the string is fully into the unit, remove the old
interconnect cable from the string.
23. Tie the upper end of the string to the end of the new interconnect cable with the small (16
pin) connector. Carefully pull the string out of the access hole near the lower PCA while
feeding the interconnect cable into the unit.
24. Replace the display housing per Procedure 7.3.
25. Remove the ground lead of the wrist strap from the EFX frame, then remove the wrist strap.
26. Connect the new interconnect cable to the lower PCA.
27. Replace the shield on the lower PCA. Replace the rear cover.
28. Check the operation of the EFX as described in Section Four.
Version 2,3 units
29. Loosen but do not remove the upper handrail clamp bolts.
30. Remove the four screws that fasten the center handrail tube clamp. See Diagram 7.24.
31. Slowly rotate the center handrail tube forward to expose the cables in the center handrail
tube. Disconnect the upper and lower interconnect cables from the mid-point connector.
Replacing the Upper Interconnect Cable
32. Remove the upper display per procedure 7.3, steps 2-7.
33. Tape the replacement upper interconnect cable to the lower end of the upper interconnect
cable. Carefully, pull the upper interconnect cable out of the top of the center handrail frame
tube.
34. Remove the tape and discard the old upper interconnect cable.
35. Connect the replacement upper interconnect cable to the upper PCA. Replace the upper
display per procedure 7.3, steps 8-13.
36. Using the mid-point connector removed in step 31, connect the upper interconnect cable to
the lower interconnect cable.