C546 Elliptical Fitness Crosstrainer
Page 6
Quarterly Maintenance
1. Remove front and rear covers.
2. Clean and lubricate the lift motor drive screw with bearing grease.
3. Check the step up and input belt tension as in Procedure 5.3.
4. Replace both covers.
On-Site Preventive Maintenance (Service Technician)
When you are called to service a EFX, perform these preventive maintenance activities:
• Perform the software diagnostics. Check LED and keypad function. Record the odometer
reading.
• Check speed sensor function (is the stride rate displayed when the unit is in operation?). If
not, see Procedure 6.4
• Does the ramp (lift) operate smoothly and quietly? If not, see Procedure 6.5.
• Visually inspect the drive belts for cracks, fraying or excessive wear.
• Inspect the power cord. If the power cord is damaged, install a new power cord.
• Visually examine all wires and check connectors and wire connections. Secure connections
and replace wiring as necessary.
.